Skyliner® Assemblies

Roof Assemblies that Meet Code

InsulationThermal BlockU-FactorApprovalASHRAE 90.1-2013, 2016, 2019, 2022 & 2025 CLIMATE ZONES MET
012345678
R-19 + R-11None0.040ASHRAE 90.1 Table A2.3.3XXXX
R-19 + R-11R-30.037ASHRAE 90.1 Table A2.3.3XXXXXX
R-25 + R-8R-30.037ASHRAE 90.1 Table A2.3.3XXXXXX
R-25 + R-11R-30.031ASHRAE 90.1 Table A2.3.3XXXXXXX
Blow-in + R-11R-50.031Hot Box Test ReportXXXXXXX
R-30 + R-11R-30.029ASHRAE 90.1 Table A2.3.3XXXXXXXX
R-25 + R-19 (10″ purlins)R-50.028Hot Box Test ReportXXXXXXXX
R-25 + R-11 + R-11R-30.026ASHRAE 90.1 Table A2.3.3XXXXXXXXX

Wall Assemblies that Meet Code

InsulationThermal BlockU-FactorApprovalASHRAE 90.1-2013, 2016, 2019, 2022 & 2025 CLIMATE ZONES MET
012345678
R-251/8″ tape0.059Hot Box Test ReportXXXXX
R-301/8″ tape0.052Hot Box Test ReportXXXXX
R-32.51/8″ tape0.044Hot Box Test ReportXXXXXXXX
R-25 + R-16 (10″ girts)1/8″ tape0.036Hot Box Test ReportXXXXXXXXX
R-25 + R-13 (10″ girts)R-50.035Hot Box Test ReportXXXXXXXXX

Simplify Your Building Envelope Compliance


Matching the right R-value, thermal blocks, and assembly pathways to your local climate zone requires precision. Let our metal building insulation experts do the heavy lifting for you. We provide custom takeoffs and verified data sheets to keep your project code-compliant and on schedule.